H2Ocala · Horse & Home Water
Reverse osmosis is a point-of-use drinking-water system
An under-sink reverse-osmosis (RO) system is a point-of-use treatment device: it connects to one fixture, usually a kitchen faucet, and uses pressure to push water through a semipermeable membrane. It makes treated water (permeate) and a separate reject-water stream, so it treats drinking and cooking water—not every tap in the house. [1] [2]

The short answer
Start here
- What it fixes: RO can reduce particular dissolved contaminants when the specific system is independently certified for that contaminant; check the product performance data sheet. [1] [2]
- What it costs: Published EPA consumer guidance lists $150–$1,000 for an RO unit, excluding maintenance; local installed price depends on the selected equipment, site plumbing, pretreatment, labor, and permit requirements. [4]
- What it will not fix: An under-sink RO unit does not make a whole house RO-treated, does not replace source investigation or certified testing, and does not automatically remove every contaminant. [1] [2] [3]
What under-sink RO is—and what it is not
An under-sink system is a point-of-use (POU) device, normally plumbed from the cold-water supply to a dedicated faucet. It may use a storage tank; tankless systems may need a booster pump or take longer to fill a glass. [2]
RO works by pressure-driven separation. The membrane allows water to pass while retaining many particles and dissolved substances in the reject stream. EPA says RO can potentially reduce contaminants including lead, PFAS, arsenic, bacteria and viruses, but not every RO unit is certified for every contaminant. Select a system whose performance data sheet names the contaminant and certification. [1] [2]
This is not a diagnosis from taste, odor, a photograph, or a quick strip. For private wells, use a state-certified laboratory and route interpretation to the Florida Department of Health. [3] The Florida DEP NELAP search can help locate certified laboratories. [5]
Use a real <table> with a caption such as “When under-sink RO may—or may not—fit.” Keep links in the relevant cells.
| What you notice or need | What it usually tells you | What to do next | Is under-sink RO enough? |
|---|---|---|---|
| You want treated water at one kitchen fixture | This is a POU use case | Compare a certified RO system with simpler filtration and the water-use tradeoff | Possibly; verify the target contaminant and certified claim [1] [2] |
| A lab or utility report identifies a contaminant | Treatment must match the measured contaminant and concentration | Read the system performance data sheet; ask the lab or public office about the result | Sometimes; not every unit removes every contaminant [2] |
| You want every shower, toilet and faucet treated | POU RO only serves its connected fixture | Discuss point-of-entry alternatives with a qualified water-treatment professional | No; RO under one sink is not whole-house treatment [1] [2] |
| The problem is low pressure, no water, leaks or a pump that will not stop | This can be a plumbing, pump or well-system fault | Call a licensed plumber or licensed water-well contractor, as applicable | No; RO is not a pump or source repair |
| The issue is bacteria or nitrate on a private well | A certified lab result and public-health guidance are needed | Contact FDOH-Marion and/or a certified lab before selecting treatment [3] [5] | Not by assumption; verify the exact system claim and source condition |
| The goal is less water waste | RO creates reject water | Compare efficiency ratings and consider a WaterSense-labeled model | Maybe; EPA says labeled systems send no more than 2.3 gallons to drain per gallon treated [1] |
Try this first: a free, quick check
Read the water source. Check whether the home is on City of Ocala water, Marion County Utilities, another utility, or a private well. Read the applicable report; a utility report is not a private-well test. [6] [7]
Write down the concern. Separate a taste, odor, scale complaint, laboratory result, or desire to treat one tap. Do not infer a contaminant from appearance or smell.
Look under the sink. Note cabinet space, cold-water and drain connections, and whether the faucet or sink needs alteration. A licensed plumber should decide the required work.
Check water-use context. EPA says typical POU RO can send five gallons or more down the drain per gallon treated; WaterSense-labeled systems send no more than 2.3. [1] [2]
Cost factors: what changes the quote
The total can depend on the certified claim; tank or tankless design; production rate; efficiency; pretreatment; connections; cabinet access; labor; permits; and future maintenance. [2] [3]
For a private well, add certified laboratory testing and possibly source or whole-house treatment. RO is not a substitute for well maintenance or correcting a contamination source. Penn State advises testing first and getting maintenance and warranty responsibilities in writing. [3]
Maintenance: the part people price too late
Maintenance is not optional. EPA says prefilters commonly need replacement about every six months and the membrane every one to five years, depending on water quality and use; the manufacturer’s instructions control. EPA also describes periodic tank draining and manufacturer-recommended sanitizing. [2]
A drop in production, low pressure, continuous drain flow, or unexpected taste or odor is a maintenance signal—not proof of a contaminant. Continuous discharge can indicate a shutoff-device problem. Follow the manufacturer and use a qualified provider for plumbing, electrical, sanitation or leaks. [2]
Ask before buying: Which cartridges and membrane are replaced, how often, and by whom? What are its rated production, reject-water ratio and certified claims? [1] [2] [3]
What RO will not fix
It will not treat the whole home. A faucet-connected POU unit does not treat shower, bath, laundry, toilet or hose water. [1] [2]
It will not identify the problem. RO selection follows a water-quality need; a strip, photo, taste or odor cannot establish a laboratory result.
It does not establish removal of every contaminant. Check the exact certified claim. EPA specifically warns that systems differ and that additional treatment may be needed depending on incoming water quality. [2] [4]
It will not eliminate maintenance. Old cartridges, a fouled membrane, a failed shutoff device or an unsanitized tank can affect operation. [2]
It will not make reject water disappear. It sends a concentrated stream to the drain; efficiency varies by model. [1] [2]
It will not repair a well, pump, pipe, water heater, drain or electrical circuit. Route those jobs to the appropriate licensed professional.
When this is not H2Ocala work
Call the right public office or licensed professional instead when the issue is outside a POU treatment decision:
Public-health, bacteria or nitrate questions: Florida Department of Health in Marion County Environmental Health, 352-622-7744; use FDOH guidance and a certified laboratory. FDOH says well testing and follow-up are separate from a treatment sales decision. [8] [9]
Private-well pump, pressure, no-water or well-construction problems: a licensed water-well contractor.
Sink, drain, supply, leak, electrical or permit work: a licensed plumber or the relevant local building office. Marion County Building Safety lists 352-438-2400 for unincorporated-county permitting questions. [10] Inside Ocala city limits, verify the City’s current permitting contact before publishing it.
Animal-water decisions: a veterinarian; do not present this page as animal-health advice.
What H2Ocala may honestly offer
H2Ocala may offer a documented site review and written price after confirming the source, intended fixture, test or utility-report evidence, equipment, installation scope, permit path and maintenance responsibility. Any offer must say whether H2Ocala supplies equipment, coordinates a licensed plumber, or only estimates. Do not promise removal beyond the product’s certified data sheet.
Questions people ask
Quick answers
Can a photo or short description settle this by itself?
No. A photo can show a visible symptom or access area, but it does not replace the source, a dated report, a laboratory result, or a property review.
What is the most useful record to bring to a review?
Bring the water source, the date and source of any report or laboratory result, readable equipment labels, and notes about where the issue appears.
Does this page provide a property-specific treatment result?
No. This page explains how to organize the next question. A written proposal and property-specific evidence are needed before scope or equipment is final.
When should a certified laboratory be involved?
For a private-well bacteria, nitrate, or contaminant question, use Florida Department of Health guidance and a certified laboratory rather than a home screen or a visual clue.
What can H2Ocala do next?
H2Ocala can organize the source, visible access details, and goals for a review. A person makes the final scope decision after the relevant evidence is available.
Sources
Public guidance behind this page
- [1] EPA WaterSense, “Point-of-Use Reverse Osmosis Systems”
- [2] EPA WaterSense, “Treating Water With Less Waste: Reverse Osmosis Systems”
- [3] Penn State Extension, “Tips for Buying Water Treatment Equipment”
- [4] EPA, “Identifying Drinking Water Filters Certified to Reduce PFAS”
- [5] Florida DEP, “NELAP Certified Laboratory Search”
- [6] City of Ocala water quality reports
- [7] Marion County Utilities, Water Quality Reports
- [8] Florida Department of Health, Well Water Facts: Disinfection
- [9] Florida Department of Health, Well Water Facts: Nitrate
- [10] Marion County Building Safety, Permitting FAQs